Buildmix Grout M40 / M60 / M80
Free-flow non-shrink cementitious grout
Pre-mixed free-flow cementitious grout — no bleeding, shrinkage-compensated. Three grades M40, M60, M80 with 28-day compressive strengths from 40 to 80 N/mm².
- ConsumptionOne 25 kg bag yields about 13.1 litres of grout
- Packaging25 kg bag
- DocumentsTDS and test reports · 7 pages
Request a quotation 0903 166 617
- Genuine Buildmix products, distributed in Vietnam by VNA
- TDS and test reports viewable right on this page
- Goods delivered with CO/CQ per batch
- Support with material selection, consumption and submittal dossiers
TDS and test reports
Buildmix Grout M40 / M60 / M80 technical dossier


Applications
- Machine foundations, rail plinths
- Anchor bolts, steel column bases
- Bridge bearings and beams
- Void filling and high-strength structural repair
- Levelling floors before tiling or timber flooring
Advantages
- Free-flowing, fills narrow gaps
- No bleeding
- Shrinkage-compensated expansion (≥ 0.1 %)
- Pre-mixed — just add water
Application steps
- Clean and saturate the concrete surface, leaving no standing water; fix tight formwork.
- Mix powder : water = 1 : 0.14 by weight (about 3.5 litres per 25 kg bag) with a mixer below 500 rpm for at least 3 minutes.
- Pour continuously from one side to avoid trapping air.
- Layers under 5 mm: use a latex–cement bonding slurry. Large pockets: add aggregate at 50–100 % of powder weight.
Technical data
| Property | Value | Standard |
|---|---|---|
| Flow spread | 22–30 cm | Suttard cylinder |
| Bleeding | 0 % | TCVN 3109:1993, ASTM C940 |
| Expansion | ≥ 0.1 % | ASTM C940 |
| Compressive strength M40 (3 / 7 / 28 days) | ≥ 25 / 35 / 40 N/mm² | TCVN 3121-11:2003 |
| Compressive strength M60 (3 / 7 / 28 days) | ≥ 40 / 50 / 60 N/mm² | TCVN 3121-11:2003 |
| Compressive strength M80 (3 / 7 / 28 days) | ≥ 45 / 60 / 80 N/mm² | TCVN 3121-11:2003 |
Packaging
- 25 kg bag
- Shelf life 6 months
Consumption
- One 25 kg bag yields about 13.1 litres of grout
- About 76 bags per 1 m³
Data per Buildmix Grout TDS, Rev. 01. Test values were obtained under laboratory conditions; contact VNA for the latest technical documents.
Need a quotation for Buildmix Grout M40 / M60 / M80?
VNA helps select materials, prepares submittal dossiers and guides application on site.